equipment

Biological Filtration

MBBR, moving-bed and fixed-bed biofilters for ammonia and nitrite removal.

Network

Project-matched biofilter partners

Process

Private & anonymized

Buyer fees

Zero

What we source

FishMatch Group sources biological filtration systems for RAS and intensive aquaculture — MBBR reactors, fixed-bed towers, denitrification reactors and integrated biological water-treatment packages.

  • MBBR moving-bed reactors
  • Fixed-bed biofilters
  • Denitrification units
  • Trickling towers
  • Kaldnes / K1 / K3 media

Private by design.

You'll never see supplier names. We run a sealed-bid process and present anonymized proposals — you choose the winner, we handle the introduction and the contract.

Start private brief

Markets we source biological filtration for

Sourcing runs the same way in every market: one structured specification, matched suppliers with real export experience for that destination, and anonymized bids priced on the same scope. Country pages below carry the local logistics, certification and installation detail.

Biological Filtration: equipment guides and planning tools

Product-type guides explain what each item does, published specification ranges and what to put in a request. Size the project with the calculators, then send one reviewed RFQ.

  • RAS biofilters

    Moving-bed, fixed-bed and sand filters that turn ammonia into nitrate.

Biofilter types compared

The biofilter converts ammonia from feed into nitrate. Size it from your peak daily feed, not from tank volume, and ask each supplier for the design nitrification rate and the temperature it assumes.

OptionTypical fitAsk the supplier to stateWatch-outs
Moving bed (MBBR)Most commercial fish and shrimp RASMedia type and fill, design feed load, aeration needed to move the mediaMedia screens and blower backup; media loss at start-up
Fixed / submerged bedSmaller or stable loads, some hatcheriesMedia surface area, cleaning method, solids toleranceClogs if upstream solids removal is weak
Trickling filterSystems that also need degassing and CO2 strippingMedia height, hydraulic loading, CO2 removal claimedLarger footprint; pumping height adds energy
Fluidised sand / granularCompact systems with steady feedingSand size, fluidisation flow, pump redundancySand loss or bed collapse if a pump stops

General buyer guidance, not a recommendation of any supplier. FishMatch Group is a buyer-side sourcing service, not a manufacturer.

Get comparable quotes in 3 steps

  1. 1

    Describe your project

    Species, target output, site and budget range. Rough numbers are fine.

  2. 2

    We review and structure it

    A person checks your request and turns it into a comparable RFQ. Procurement help is for projects of USD 250,000 and above.

  3. 3

    Compare proposals

    You receive proposals on the same basis. Supplier identities stay private until you choose to proceed.

Request biofilter quotes

Related categories

Short answer

How do you source Biological Filtration for a commercial aquaculture project?

Start from the process requirement — biomass, flow, water quality target and site constraints — not from a product catalogue. FishMatch Group converts that requirement into a specification for Biological Filtration, sources it from matched manufacturers and integrators across Europe, Asia and the Americas, and returns like-for-like quotations with lead times, energy consumption and lifetime running cost stated in the same format.

What we compare:
Scope, capacity, energy use, lead time and total cost of ownership
Typical turnaround:
Depends on scope and site data; no turnaround is guaranteed
Delivery terms:
Quotations normalised to EXW / FOB / CIF so prices are like-for-like
Cost to buyers:
No fee charged to the buyer

Before you request quotes

Equipment scope

What equipment does a commercial aquaculture project actually need?

A grow-out project typically needs holding infrastructure (tanks, ponds or cages), water movement (pumps, piping, valves), aeration or oxygenation, water treatment appropriate to the system, feeding equipment, grading and handling gear, monitoring and alarms, and backup power. RAS adds mechanical filtration, biofiltration, degassing, disinfection and tighter process control. Hatchery and processing scopes are specified separately.

Which equipment should be specified before requesting quotes?

Specify the items whose sizing changes everything downstream: design biomass and stocking density, water exchange or recirculation rate, oxygen demand at peak temperature, and installed pumping head. With those four fixed, suppliers can quote aeration, filtration, pumps and power on the same basis. FishMatch calculators produce these figures and attach them to the RFQ.

Can equipment be sourced in stages?

Yes, and phased procurement is common. The usual sequence is water supply and holding infrastructure, then aeration and treatment, then automation and monitoring, then processing and cold chain. Staging works when interfaces and capacity headroom are defined at the start; otherwise later phases force replacement rather than addition.