A recirculating aquaculture system is a chain of linked packages — filtration, biofiltration, CO₂ removal, oxygen, disinfection, pumping, controls, backup power and effluent — all sized from one design basis: species, biomass and peak feed load. Fix that basis and the scope of each package before asking suppliers to quote, so you compare like with like.
Planning guidance only. Final sizing must be done and signed off by a qualified RAS engineer.
1. Design basis: species, biomass and feed load
Every package below is sized from the same basis: species, annual output, harvest weight, maximum standing biomass and peak daily feed. Agree it in writing before any supplier sizes equipment, or quotes cannot be compared.
Ask every supplier to state
- Peak feed per day (kg) and feed protein %
- Maximum stocking density per tank group
- Water temperature and salinity range
2. Water source, intake and make-up water
Source type (well, municipal, surface, sea), chemistry, temperature and daily make-up volume. Pre-treatment needs depend on the source analysis, not on the supplier's standard design.
Ask every supplier to state
- Lab water analysis attached
- Make-up water % of system volume per day
- Pre-treatment included or excluded
3. Mechanical filtration and solids removal
Drum or disc filters, screen mesh size, backwash water use and fine-solids handling. Solids load follows feed load.
Ask every supplier to state
- Screen micron size
- Backwash water and power use
- Sludge flow to effluent treatment
4. Biofiltration (nitrification)
Media type (MBBR, fixed bed, trickling), media volume and specific surface area, sized from the daily ammonia load produced by feed.
Ask every supplier to state
- Design ammonia load (g TAN/day) and how it was derived
- Media volume and specific surface area
- Assumed nitrification rate at design temperature
5. Degassing and CO₂ stripping
CO₂ builds up with feed and oxygen use. Strippers, aeration columns and air-to-water ratios must be stated with the target CO₂ level.
Ask every supplier to state
- Target dissolved CO₂ (mg/L)
- Stripper type and air-to-water ratio
- Fan power
6. Oxygenation
Oxygen demand from biomass and feed, supply method (LOX, on-site generator, cones, low-head oxygenators) and the backup oxygen source.
Ask every supplier to state
- Design oxygen demand (kg O₂/day)
- Primary and emergency oxygen supply
- Dissolved-oxygen setpoint per tank
7. Disinfection: UV and/or ozone
UV dose and the flow it treats, ozone dosing and residual control. State whether intake water, recirculating water or both are treated.
Ask every supplier to state
- UV dose at end of lamp life
- Treated flow (side-stream or full flow)
- Ozone residual monitoring
8. Pumping and hydraulics
Recirculation flow, tank exchange rate, total head and pump efficiency drive the largest continuous power use in most RAS.
Ask every supplier to state
- Design flow and total dynamic head
- Pump efficiency and installed kW
- Duty/standby pump arrangement
9. Tanks and production layout
Tank volume, number, material and grouping into independent loops for biosecurity and staged production.
Ask every supplier to state
- Tank count, volume and material
- Number of independent loops
- Purge/depuration tanks included?
10. Monitoring, controls and alarms
Sensors (O₂, temperature, pH, CO₂, flow, level), PLC/SCADA scope and remote alarms. Specify what is monitored per tank versus per loop.
Ask every supplier to state
- Sensor list per tank and per loop
- Alarm escalation and remote access
- Software licences and support term
11. Backup power and redundancy
Generator capacity, automatic transfer time and which loads it carries. Single points of failure (one blower, one oxygen line) should be named and priced out.
Ask every supplier to state
- Generator kVA and transfer time
- Loads carried in a power failure
- List of single points of failure
12. Effluent, sludge and discharge permit
Sludge thickening, treatment and disposal route, matched to the local discharge permit. Often excluded from equipment quotes and added later.
Ask every supplier to state
- Effluent treatment scope included or excluded
- Sludge volume and disposal route
- Permit limits the design meets
13. Building, civil works and installation
Building, floor loading, insulation, HVAC, civil works, installation, commissioning and training — the lines most often left out of an equipment-only price.
Ask every supplier to state
- Which of these are in scope (FAT/SAT, installation, commissioning)
- Performance guarantees and their test conditions
- Warranty and spare parts
From design scope to comparable quotes
Estimate the budget with the RAS cost calculator, then use the FishMatch procurement platform to send one scope to several suppliers. Every request is reviewed by a person; FishMatch is supplier-neutral and handles projects from USD 250,000.