Backup power for aquaculture that survives real outages.
RAS, hatcheries, shrimp farms and cold storage are life-critical loads. FishMatch prepares neutral, bankable power engineering — generators, solar-hybrid, LFP battery, UPS, ATS and remote monitoring — and issues RFQs to project-matched suppliers under NDA.
The full backup-power stack
Diesel & gas generators
Prime and standby gensets for aeration, life-support, freezers and pumping.
- • Load audit → prime kW & standby kW sizing
- • Fuel storage, bunding, day tank, spill containment
- • Sound attenuation, exhaust routing, cooling
Solar-hybrid systems
PV + LFP battery + diesel backup — the modern default for coastal and remote aquaculture.
- • Load-shift aeration/pumping into daylight
- • Cut diesel spend 50–90% depending on latitude
- • Grid-tied, hybrid and off-grid configurations
Battery storage (LFP)
Ride-through and autonomy for life-critical loads on RAS, hatcheries and cold storage.
- • Sized on autonomy hours × critical load, not headline kWh
- • LFP chemistry for high cycle life and thermal safety
- • Integrated with genset via ATS or hybrid inverter
UPS & ATS
Uninterrupted power for controls, sensors, monitoring and refrigeration transitions.
- • Online double-conversion UPS for PLCs and monitoring
- • Automatic transfer switches with genset priority logic
- • Redundant paths for life-support and freezers
Remote monitoring & alarms
Because unmanned outages kill fish, shrimp and margin.
- • SMS/app alarms on power loss, ATS failure, low fuel
- • Cloud dashboards for gen hours, kWh, battery SoC
- • Integrated with farm SCADA or standalone
Fuel & maintenance strategy
OPEX is where most projects underestimate — model it before RFQ.
- • Genset hours target vs LCOE with PV+battery
- • Fuel supply agreements and price hedging
- • Preventive maintenance plan aligned with warranty
Model your power stack live
Adjust load and autonomy to match your farm. Send the result as a pre-filled, confidential RFQ.
Aquaculture Generator Sizing Calculator
This tool sizes a prime or standby generator for aquaculture from the farm's critical kW load, applies motor-starting headroom and site derating (altitude, temperature), and estimates fuel burn and monthly fuel cost.
≈3% per 300 m above 1000 m.
≈2% per 5 °C above 40 °C ambient.
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Battery Storage Sizing Calculator
Aquaculture critical loads — oxygenation, biofilter pumps, alarms — cannot tolerate outages. This tool sizes an LFP battery bank in kWh from critical-load kW, autonomy hours and depth-of-discharge (DoD).
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Aquaculture Power Requirement Calculator
Every backup-power design starts from the same question: how many kW does the farm actually consume — and how many of those kW are critical (life-support) versus non-critical (lights, offices, processing)? This tool sums the main aquaculture loads so you can size a generator, UPS or solar-hybrid system correctly.
Not every load runs at max at once.
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Solar Aquaculture ROI Calculator
Solar PV cuts pumping, aeration and RAS energy bills 30–90% on well-sited farms. This tool estimates annual generation, energy savings, payback years and 10-year ROI from CAPEX, irradiance and grid tariff.
Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.
Common mistakes we catch at RFQ stage
- Sizing the genset on peak instantaneous load instead of the true life-critical envelope
- Ignoring fuel logistics on remote sites — genset arrives, fuel supply chain doesn't
- Buying batteries on kWh headline instead of usable-energy-under-real-cycle
- No ATS logic for cold-chain freezers — a bad startup sequence trips the whole plant
- Missing UPS on controls / SCADA — power returns but the farm is blind for hours
- Optimising LCOE on paper but forgetting warranty and preventive-maintenance OPEX