FishMatch Group · Energy Resilience

Backup power for aquaculture that survives real outages.

RAS, hatcheries, shrimp farms and cold storage are life-critical loads. FishMatch prepares neutral, bankable power engineering — generators, solar-hybrid, LFP battery, UPS, ATS and remote monitoring — and issues RFQs to project-matched suppliers under NDA.

The full backup-power stack

Diesel & gas generators

Prime and standby gensets for aeration, life-support, freezers and pumping.

  • Load audit → prime kW & standby kW sizing
  • Fuel storage, bunding, day tank, spill containment
  • Sound attenuation, exhaust routing, cooling

Solar-hybrid systems

PV + LFP battery + diesel backup — the modern default for coastal and remote aquaculture.

  • Load-shift aeration/pumping into daylight
  • Cut diesel spend 50–90% depending on latitude
  • Grid-tied, hybrid and off-grid configurations

Battery storage (LFP)

Ride-through and autonomy for life-critical loads on RAS, hatcheries and cold storage.

  • Sized on autonomy hours × critical load, not headline kWh
  • LFP chemistry for high cycle life and thermal safety
  • Integrated with genset via ATS or hybrid inverter

UPS & ATS

Uninterrupted power for controls, sensors, monitoring and refrigeration transitions.

  • Online double-conversion UPS for PLCs and monitoring
  • Automatic transfer switches with genset priority logic
  • Redundant paths for life-support and freezers

Remote monitoring & alarms

Because unmanned outages kill fish, shrimp and margin.

  • SMS/app alarms on power loss, ATS failure, low fuel
  • Cloud dashboards for gen hours, kWh, battery SoC
  • Integrated with farm SCADA or standalone

Fuel & maintenance strategy

OPEX is where most projects underestimate — model it before RFQ.

  • Genset hours target vs LCOE with PV+battery
  • Fuel supply agreements and price hedging
  • Preventive maintenance plan aligned with warranty
Interactive tools

Model your power stack live

Adjust load and autonomy to match your farm. Send the result as a pre-filled, confidential RFQ.

Embedded tool

Aquaculture Generator Sizing Calculator

This tool sizes a prime or standby generator for aquaculture from the farm's critical kW load, applies motor-starting headroom and site derating (altitude, temperature), and estimates fuel burn and monthly fuel cost.

≈3% per 300 m above 1000 m.

≈2% per 5 °C above 40 °C ambient.

Recommended genset
136 kVA
109 kW rated · pf 0.80
Site-derated capacity
92%
alt 3% + temp 5%
Fuel burn
20.4 L/h
≈ 2,446 L/month
Monthly fuel cost
$2,690
@ $1.10/L, 4 h/day

Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.

Embedded tool

Battery Storage Sizing Calculator

Aquaculture critical loads — oxygenation, biofilter pumps, alarms — cannot tolerate outages. This tool sizes an LFP battery bank in kWh from critical-load kW, autonomy hours and depth-of-discharge (DoD).

Usable energy required
102.1 kWh
Battery nameplate
120.2 kWh
LFP, DoD 85%
Estimated CAPEX
$54,068
@ $450/kWh installed

Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.

Embedded tool

Aquaculture Power Requirement Calculator

Every backup-power design starts from the same question: how many kW does the farm actually consume — and how many of those kW are critical (life-support) versus non-critical (lights, offices, processing)? This tool sums the main aquaculture loads so you can size a generator, UPS or solar-hybrid system correctly.

Not every load runs at max at once.

Total demand load
79.1 kW
98.8 kVA @ pf 0.8
Critical (life-support) load
78 kW
must ride through outages
Non-critical load
15 kW
Connected load
93 kW
diversity 85%

Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.

Embedded tool

Solar Aquaculture ROI Calculator

Solar PV cuts pumping, aeration and RAS energy bills 30–90% on well-sited farms. This tool estimates annual generation, energy savings, payback years and 10-year ROI from CAPEX, irradiance and grid tariff.

Annual generation
148,044 kWh/yr
148 MWh/yr
Annual energy savings
$26,648
System CAPEX
$90,000
$900/kWp installed
Simple payback
3.4 years
10-year ROI
196%

Estimates Only: This calculator is provided for general informational purposes only. Results are approximate and may contain errors, omissions, or outdated information. They do not constitute legal, financial, engineering, tax, technical, or professional advice. Users are solely responsible for independently verifying all calculations, specifications, prices, regulations, and requirements with qualified professionals before making any decisions. By using this calculator, you acknowledge that the website owners, operators, and affiliates accept no responsibility or liability for any loss, damage, or decisions resulting from its use.

Common mistakes we catch at RFQ stage

  • Sizing the genset on peak instantaneous load instead of the true life-critical envelope
  • Ignoring fuel logistics on remote sites — genset arrives, fuel supply chain doesn't
  • Buying batteries on kWh headline instead of usable-energy-under-real-cycle
  • No ATS logic for cold-chain freezers — a bad startup sequence trips the whole plant
  • Missing UPS on controls / SCADA — power returns but the farm is blind for hours
  • Optimising LCOE on paper but forgetting warranty and preventive-maintenance OPEX

Turn your load audit into a bankable RFQ.

Neutral engineering, confidential sourcing, comparable bids. Buyers never pay.